- Content: Inner Rotor + Stator + Diagram Control Unit + Plate + HT Coil + Fitting Set + Mounting Instructions
- Ignition timming adjustment using MVT Diagram Control Unit RJ34/6,7,8 : 0,35mm before TDP (Top Dead Point) on 45mm stroke crankshafts and 0,40mm before TDP on original 40mm stroke crankshafts.
- Ignition timming adjustment using MVT EPROM Control Unit EPROM1,2,3,4,5 : 2.9mm before TDP (Top Dead Point).